Coligulus wrote:
If I remember correctly the SaraSoft software while supporting a number of Nokia handset's is currently not able to do anything with the model you have listed. The model exists in the software but I have tried multiple times with different cable and handset combinations and been unable to acquire anything from the device. I have always had to resort to the Ocularis v1.0. Even trying to use XRY I had issues, however there have been a couple of updates to XRY since I last tried so this may have changed, however, I would think at this point only for a logical examination if it works at all.
You would only be able to read the PM tables anyway with SaraSoft if it was possible as currently there is no way I am aware of to get a full dump of the device.
I'd check the cable that you're using. We've been extracting PM records from this model using HWK (SaraSoft) and XRY for about a year.
↧